 | 2000 IPS Day and Night Service change from Extension | |
 | Putting a system into Night service
Using command 9000. CM 9000 > extension,key number : F13xx (where xx is the tenant number). For example CM 9000 > 2000,08 : F1301.
This would put a night service key on extension 2000 on key 8 for tenant 1. As w |
|
 |
 | Setting the Call Forward Don't Answer (No Answer) timer. | |
 | Setting the Call Forward Don't Answer (No Answer) timer.
For a detailed programming and explanation please refer to the Feature Programming Manual, the chapter on Call Forwarding-Don't Answer.
There are two ways of setting the Call Forward - Don't |
|
 |
 | Unable to set a call forward on Dterm (Restrict) | |
 | Unable to set a call forward on Dterm (Restrict)
Check the following commands:
CM 1500 > restriction class e.g.15 > 1 (this means that users with service restriction class 15 can set a call forward all calls).
CM 1510 > 15 : 1 – This enables cl |
|
 |
 | View existing data programming. | |
 | View existing data entered.
To view data entries, type in the command, press the spacebar, type in the second data, press the spacebar key and the second data value is displayed. By pressing enter /return key, the first data values are stepped through. |
|
 |
 | Enabling Silent Monitoring | |
 | Silent Monitoring
CM 15103 > class number : 0 (Restrict) / 1 (Allow) - Allows users to monitor other users.
CM 15104 > class number : 0 (Restrict) / 1 (Allow) - Allows users to be monitored.
CM 08 > 259 : 0 (Off) / 1 (On) - Switches warning tone on o |
|
 |